D1-10 - Dual Controller Model D1-10 - Single Controller Model
Chassis Configuration Up to 5 Disk Enclosure Units (DEU) can be connected to the Base Unit.
Up to 12 HDDs can be mounted in the Base Unit or a DEU.
SAS & SATA HDDs can be mounted in the same Base Unit or DEU.
Form Factor Base Unit : 2U Rack Storage Unit; EIA Standard Height 2 – EIA
Disk Enclosure Unit : 2U Rack Storage Unit; EIA Standard Height 2 – EIA
Host Interface Fiber Channel (FC-AL, Fabric); Max. transfer speed 400MB/S*1
Number of Host Ports 4 FC Ports 2 FC Ports
Cache memory Capacity 2GB (1GB per controller) 1GB
Battery Backup Time 24H - Standard
120H - With Optional External 1U Battery Backup Unit
Hard Disk Drives SAS 73GB (15,000rpm) , 147GB (15,000rpm) , 300GB (15,000rpm)
SATA 500GB (7,200rpm) , 750GB (7,200rpm)
Hard Disk Drive Interface SAS (Max. Transfer Speed 300MB/S) SATA (Max. Transfer Speed 300MB/S)
Maximum N° of HDDs 72 Units
Supported RAID Levels SAS HDDs: RAID-0*2, 1, 5, 10, 50, 6
SATA HDDs: RAID-6
Device Capacity   Min. Configuration*3 Max. Configuration*4 Min. Configuration*3 Max. Configuration*3
SAS 73Gb HDD 71GB 4.1TB 71GB 4.1TB
147Gb HDD 142GB 8.2TB 142GB 8.2TB
300Gb HDD 288GB 16.5TB 288GB 16.5TB
SATA 500Gb HDD 1.9TB 28.3TB 1.9TB 28.3TB
750Gb HDD 2.9TB 42.5TB 2.9TB 42.5TB
Dimension (W×D×H)
(Excluding Bezel)
Base Unit (2U) : 445×540×86.5 mm; Disk Enclosure Unit (2U) : 445×540×86.5 mm
Weight Base Unit : 31kg or Less; Disk Enclosure Unit (2U) : 29kg or Less
Power Supply AC100~240V Single Phase 50/60Hz
Number of AC Line Base Unit DEU Base Unit DEU
2 2 2 2
Max. Power Consumption*5 SAS 610VA/590W 450VA/430W 610VA/590W 450VA/430W
SATA 550VA/530W 380VA/370W 550VA/530W 380VA/370W
Inrush Current (Peak Time) 17Ao-p/AC line 17Ao-p/AC line 17Ao-p/AC line 17Ao-p/AC line
Temperature & Humidity When Operating: 5-40°C, 10-80% ; When Stored: 10-60°C, 5-80%
Supported OS Windows Server 2003 (SP1 & SP2) & Windows Server 2003 R2 (IA-32 & x64 Versions)
Red Hat Entrprise Linux AS3 / AS4
VMWare ESX 3.0.1 (for both SAS & SATA HDD Configurations)
* For additional OS Support, including : HP-UX 11, Solaris 9, Solaris 8, AIX

Please Contact NEC
Component Redundancy Controller, Cache, Power Supplies, Fans Power Supplies, Fans
The capacity values are calculated based on 1GB=1,000,000,000B and 1TB=1,000,000,000,000B.
*1 1Gbps/2Gbps modes are also supported through a change of setting.
*2 Do not use RAID-0 unless the customer understands that RAID-0 has no redundancy.
*3 When using SAS HDDs: RAID-1 Minimum Configuration: 2x SAS HDDs; When using SATA HDDs: RAID-6 Minimum Configuration: 6x SATA HDDs
Minimum HDD Configuration Requirement: 3x HDDs mounted in the Base Unit.
*4 When using SAS HDDs: RAID-6 Maximum Configuration: 72x SAS HDDs; When using SATA HDDs: RAID-6 Maximum Configuration: 72x SATA HDDs
*5 Safety Margin of 30% over VA value is required for UPS.