Note:
- Only BMC Expressscope V2 or newer can monitor hard disks. As
consequence, no hard disk event will appear in SEL log file with
other BMC.
- Always make sure to update the BMC to latest version of firmware
using BOOT_CD before
escalating the case with logs.
- This table does not cover Fault Tolerant, Flexpower nor
Sigmablade servers. Please refer to dedicated pages on those
products for more informations.
| NEC Corporation Systems (systems developped in
Japan) |
NEC BMC Name
(clic on title below to open dedicated page) |
Optional
or
Embedded |
Features |
IPMI SEL log using... |
COLLECT
log using... |
| Monitoring, remote power control and SNMP trap |
SMTP Alerts |
LAN mode and configuration |
Remote KVM
Remote Media |
...
BOOT_CD
TID0604210929
|
...
ExpressBuilder
TID0604210929
|
...
ESMPro Agent
Win.TID0603081022
Lin.TID0710031501 |
...
Management
Port Web Server
TID0806031032
|
...
ESMPro Agent
Win. TID0408121449
Lin. TID0710031500 |
| BMC (1) |
Embedded
|
YES
|
NO
|
Shared (LAN1),
cfg by ExBldr
|
NO
|
1.0.x
|
YES
|
YES
|
NO
|
YES
|
| RMC (2) |
Optional
|
YES
|
NO
|
Shared (LAN1), cfg by ExBldr
|
NO
|
1.0.x
|
YES
|
YES
|
NO
|
YES
|
| ARMC (2) |
Optional
|
YES
|
YES
|
Dedicated
(MNT), cfg by ExBldr
|
YES KVM
only
|
1.0.x
|
YES
|
YES
|
NO
|
YES
|
| ExpressScope V1 (3) |
Embedded
|
YES
|
YES
|
Dedicated (MNT), cfg by ExBldr
|
YES, billable license
|
1.0.x
|
YES
|
YES
|
NO
|
YES
|
| ExpressScope V2 (4) |
Embedded
|
YES
|
YES
|
Dedicated
(MNT), cfg by ExBldr or SETUP
|
YES activated
by free license
|
1.0.x
|
YES
|
YES
|
YES
|
YES
|
| Expressscope
V2+ (5) |
Embedded
|
YES
|
YES
|
Dedicated (MNT)
or Shared
(LAN1), cfg by ExBldr or SETUP
|
YES activated by free license
|
1.5.x
|
YES
|
YES
|
YES
|
YES
|
(1) 120Rd-1,
120Rf-2, 120Lg
(2) 110Ej, 120Lh, 120Re-1, 120Rg-2, 120Rf-1, 120Rh-2, 140Re-4,
140Hf.
PN of optional BMC are 6932340000 for A-RMC, and 6932330000 for
RMC. Check BOM of your server.
(3) 110Ek, 120Li, 120Rg-1, 120Ri-2, 120Bb-6,120Bb-d6,
120Bb-m6
(4) 120Ei, 120Lj, 120Rh-1, 120Rj-2,
(5) T120a-M, R120a-1, R120a-2, 140Rf-4, R140a-4, T120b-M, R120b-1,
R120b-2, R140b-4, T120b-E, B120a, B120a-d, B120b, B120b-d,
B120b-h
|
| NEC Computers Systems (systems developped in
France) |
NEC BMC Name
(clic on title below to open dedicated page) |
Optional
or
Embedded |
Features |
IPMI SEL log using... |
COLLECT
log using... |
| Monitoring, remote power control and SNMP trap |
SMTP Alerts |
LAN mode and configuration |
Remote KVM
Remote Media |
...
BOOT_CD
TID0604210929
|
...
ExpressBuilder
TID0604210929
|
...
ESMPro Agent
Win.TID0603081022
Lin.TID0710031501 |
...
Management
Port Web Server
TID0806031032
|
...
ESMPro Agent
Win. TID0408121449
Lin. TID0710031500 |
| mBMC PC87431
(1') |
Embedded
|
YES
|
NO
|
Shared (LAN1), cfg by ExBldr
|
NO
|
1.0.x
|
YES
|
YES
|
NO
|
YES
|
| ESB2 BMC (2') |
Embedded
|
YES
|
NO
|
Shared (LAN1),
cfg by SYSCFG tool
|
NO
|
1.0.x
(txt file)
|
NO
|
YES
|
NO
|
YES
|
| SMDC M329
(3') |
Optional
|
YES
|
NO
|
Shared (LAN1), cfg by TSO CD
|
NO
|
1.0.x
(txt file)
|
NO
|
NO
|
NO
|
NO
|
| iBMC (4') |
Embedded
|
YES
|
YES
|
Shared (LAN1),
cfg by SYSCFG tool
|
NO
|
2.0.x
(txt file)
|
NO
|
NO
|
NO
|
NO
|
| ServerEngine (5') |
Embedded BMC
and optional
extention called RMM3
|
YES
|
YES
|
Shared (LAN1) with BMC embedded, Dedicated with
additional port of RMM3, cfg by SYSCFG tool
|
NO with embedded
YES with
RMM3
|
2.5.x
(txt file)
|
NO
|
NO
|
NO
|
NO
|
(1') 120Eg
(2') 120Eh2
(3') SA2500R-1
(4') SI1120R-1 / SI1520 / SI1720
(5') SI2520 / WI2730 |
NEC BMC
|